Low head pressure normal suction - The low evaporator pressure is caused by the compressor being starved of refrigerant. The compressor is trying to draw refrigerant from the evaporator through the suction line, but the liquid line restriction is preventing refrigerant from entering the evaporator. This will cause the compressor to put the evaporator in a low pressure …

 
180 suction line pressure 320 discharge 10 degree temp split. No temp difference across the filter drier. I cleaned coils and checked airflow just to eliminate the variables. I recovered the refrigerant, changed the filter drier, charged about 2lbs before starting the compressor and the low side shot right up to 170. System holds about 8 lbs total.. Dryden transfer station hours

Explore a comprehensive guide to troubleshooting low suction pressure and maintaining normal head pressure in HVAC systems. Learn about the causes, …How to Check Subcooling. Attach the thermometer to the liquid line. This time, near the condenser. Then take the head pressure in Psi and convert it to the temperature on the pressure/temperature chart. Assuming you are dealing with a R22 system, let’s say the head pressure is 260Psi. This will convert to 120F.I have a heat pump with very low pressure on the suction side. I put a new thermastatic control valve thinking the valve my not be working. I still have very low pressure side( Pressure is 10-15 with normal at 45) Evaporator is new with sensing bulb properly installed. I noticed evaporator freezing although the blower is working.Because the pump's suction pressure, PIP, is known, the pressure increase to be exerted by the pump, Δ ppump = pd − PIP, is easily found. This value, however, if converted to head, gives exactly the pump's required head, i.e., the TDH value as found from the following formula: (5.38) where. TDH = total dynamic head, ft.The high side pressure, in contrast, refers to the refrigerant pressure in the discharge line. This is basically the pressure after the compressor. Even though the ideal pressure range for an R-401A air conditioner falls in the range of 110-140, its low side pressure should not be less than 100 psi, nor should it be more than 160 psi. Why this ... Came across another Rheem recently with a high head pressure in heat mode. Its a RPPL. Head pressure slowly climbs to above 600, suction pressure is normal not low at all. Airflow inside is okay... static pressure is .7inWc. Coils are clean. In cooling mode the charge looks damn near perfect... 11 degrees subcooling and 9-11 degrees superheat. My suction is running at 45psi and head is at 110psi. I checked evap coil and filter and both were clean, so I figured it was low on R22. I added 7 lbs. (factory charge is 7.25 lbs) and pressures did not change. The suction line is frosting up to the compressor. I'm starting to think I have a bad reversing valve.In the cooling mode this will result in low suction pressure and low discharge pressure. Sub cooling would be extra high. However, heatpumps can't always be charged accurately using sub cooling alone. Usually "a stuck check valve" can be freed-up by using a strong magnet.Nov 11, 2016 · 4. Post Likes. Very high suctuion and head pressure on heating mode. Hello, I have a Rheem (2015) heat pump 2ton 410A, on cooling mode the system runs great; suction and liquid pressure are ok 185/360, super heat 10 F, with 90F outdoor temperature, now the winter is coming and the system on heating mode the gages read high pressure on both ... Came across another Rheem recently with a high head pressure in heat mode. Its a RPPL. Head pressure slowly climbs to above 600, suction pressure is normal not low at all. Airflow inside is okay... static pressure is .7inWc. Coils are clean. In cooling mode the charge looks damn near perfect... 11 degrees subcooling and 9-11 degrees superheat. In a 2-ton capillary tube system, the unit does not develop full capacity. Heat pressure is low and suction pressure is high. What is the problem?NPSHr —The net positive suction head required is the measurement of the amount of fluid pressure energy required by the pump. The NPSH available to the pump should be more than what the pump requires. If there is not enough NPSHa, the pump will cavitate. As a result, the performance and reliability can be compromised. In an even … At an absolute pressure of 101.3 kN/m 2 (normal atmosphere) the boiling starts at 100 o C. Net Positive Suction Head - NPSH. The Net Positive Suction Head - NPSH - can be defined as. the difference between the Suction Head, and; the Liquids Vapor Head; and can be expressed as. NPSH = h s - h v (3) or, by combining (1) and (2) Jul 5, 2011 · normal suction low head pressure. im in the field 3 years now and this is the first time ive come across this. residential split system 1.5 tons and i had a good suction pressure but my head pressure was super low, only 150-160. the strange thing is operations seemed pretty normal. cold suction line, warm liquid line, condenser was putting out ... Low Side Pressure (Suction Pressure) 110-140 psi: 70-140 psi: High Side Pressure (Condensing Pressure) 300-350 psi: 250-400 psi: The above pressure range is based on the following operating conditions. ... Sometimes, improper brazing work may not cause a leak during normal days when the mini split working pressure is low.High head- normal suction Hey guys- heading back out tomorrow on a no cool call back. First call found pressures (410A) 110/655. ... Well, now it has very low suction pressure plus suction-line icing-up; entirely different symptoms: Simple, when checking for restrictions:Jul 8, 2019 · High Suction Pressure R-410a. i went to check an 3.5 ton a/c brand is a ICP (international comfort products) Model WAPL424A1, not cooling my pressures were low side 185 to 190 and high side was around 350 on a 107F hot day. It has a piston as a metering device and compressor was running at 11.50 amps and RLA is 17.25 amps. The most common causes of pressure in the head and face include allergies, ear infections, the common cold, muscle tension, sinusitis, stress and tension headaches. Increased intra... At an absolute pressure of 101.3 kN/m 2 (normal atmosphere) the boiling starts at 100 o C. Net Positive Suction Head - NPSH. The Net Positive Suction Head - NPSH - can be defined as. the difference between the Suction Head, and; the Liquids Vapor Head; and can be expressed as. NPSH = h s - h v (3) or, by combining (1) and (2) There are three main reasons why a compressor will simultaneously have a low head pressure and a high suction pressure: 1. Bad (leaky) compressor valves; 2. …The normal position for a suction service valve during normal operation is ____. back seated. front seated. cracked off the back. mid-seated. 16 of 21. ... Which of the following is another type of low ambient temperature head pressure control? Choose matching definition. air volume control using shutters and fan cycling.The fact that these readings are normal indicates the low suction pressure is not caused by low refrigerant, but insufficient heat getting to the evaporator. CAUSE …How to Fix Low Suction Pressure Issues. If there is excessive moisture in system: replace the drier. If you find a flattened or kinked hose: replace the hose. If the compressor pistons have worn out: replace the compressor. If there is a shortage of refrigerant: add refrigerant. If there is a leaking compressor head gasket: replace the head gasket.A normal blood pressure range, according to WebMD, occurs when the systolic number is 120 or below and the diastolic number is 80 or below. High and low blood pressure problems aff...Low temp freezer running 404a. evaporator temp should be around -20 degrees - which is 15psi for 404a. (but it wont be quite that low until the box gets closer to proper temp. normal head pressure for 100 degree ambient would be 130 degree condensing temp which is 350 psi for 404a.Nov 11, 2016 · 4. Post Likes. Very high suctuion and head pressure on heating mode. Hello, I have a Rheem (2015) heat pump 2ton 410A, on cooling mode the system runs great; suction and liquid pressure are ok 185/360, super heat 10 F, with 90F outdoor temperature, now the winter is coming and the system on heating mode the gages read high pressure on both ... pressure is the pressure required to boil a liquid at a given temperature. Soda water is a good example of a high vapor pressure liquid. Even at room temperature the carbon dioxide entrained in the soda is released. In a closed container, the soda is pressurized, keeping the vapor entrained. Vapor Pressure 0 5 10 15 20 25 40 60 80 100 120 140 ...Number 2 is incorrect, metering device part depends on system to system. High load is correct. Look at your liquid line temps, subcooling and approach temps. They will help diagnose high head issues. There is another cause of high head pressure, mismatched (higher btu) compressor. Different refrigerant in the system.Do you find yourself constantly frustrated with low water pressure in your home? Whether it’s a weak shower, slow-filling toilet, or inadequate water flow in your kitchen sink, low...Fig. 3.55 illustrates this by plotting the pump discharge head vs. flow for high- and low-suction tank conditions. The control valve, however, tries to maintain a steady pressure. As a result, the flow rate varies as the suction pressure varies. In some cases, the flow rate may drop to below the recommended minimum at very low head conditions.Apr 22, 2024 · If the suction pressure is 45 psi, (which converts to 22 ° F) and the suction temp is 32 ° F, the system still has 10 ° F of superheat. The fact that these readings are normal indicates the low suction pressure is not caused by low refrigerant, but insufficient heat getting to the evaporator. CAUSE #2: Defective, plugged, or undersized ... HIGH SUCTION PRESSURE / LOW HEAD PRESSURE ISSUE. Hey guys, need some help i am working on a carrier unit with a Scroll Compressor. I am getting 80 …Liebert A/c unit with low suction pressure. To any one who can help. I have a Liebert Computer room A/C unit dating back from 1984. I do not have the model Number. I am guessing it to be approximately 12 tons. Having trouble with compresor one circuit freezing after the TXV and low suction pressure.If the system suction pressure on a fixed metering device type unit is too high; the potential causes are; C. Flooded Evaporator Coil, High Evaporator Head Load, Dirty Condenser Coils, Compressor Valve Failures. TXV system problems can exhibit the five following symptoms: a. Normal suction pressure & superheat, with low or high …Do it until all the pressure from the low side AC is out before disconnecting everything you used. e. Disconnect the Compressor. Now, after releasing the pressure from the low side AC, disconnect the line connecting the low-pressure side of the compressor to the suction line. Finally, open the valves.Number 2 is incorrect, metering device part depends on system to system. High load is correct. Look at your liquid line temps, subcooling and approach temps. They will help diagnose high head issues. There is another cause of high head pressure, mismatched (higher btu) compressor. Different refrigerant in the system.There are three main reasons why a compressor will simultaneously have a low head pressure and a high suction pressure: 1. Bad (leaky) compressor valves; 2. …4. Post Likes. Very high suctuion and head pressure on heating mode. Hello, I have a Rheem (2015) heat pump 2ton 410A, on cooling mode the system runs great; suction and liquid pressure are ok 185/360, super heat 10 F, with 90F outdoor temperature, now the winter is coming and the system on heating mode the gages read high pressure on both ... The normal operating pressures for R404A in a walk-in cooler typically range between 55-70 psi on the low side and 210-250 psi on the high side. However, these pressures can vary based on the specific application and ambient conditions. An expansion device that is stuck open will cause A. Low suction pressure B. ... When measuring evaporator superheat on a commercial system that has a long suction line, the pressure reading should be taken at the A. Compressor inlet B. Evaporator outlet C. Condenser ... An evaporator used to chill liquids is operating within normal superheat ...In these scenarios, service technicians will usually find the system to have a higher-than-normal suction pressure along with a lower-than-normal head pressure. They will also notice lower amperage draws from the compressor, normal-to-a-bit-high evaporator superheats and condenser subcooling, and often a higher-than-normal …Because the pump's suction pressure, PIP, is known, the pressure increase to be exerted by the pump, Δ ppump = pd − PIP, is easily found. This value, however, if converted to head, gives exactly the pump's required head, i.e., the TDH value as found from the following formula: (5.38) where. TDH = total dynamic head, ft.How to Fix Low Suction Pressure Issues. If there is excessive moisture in system: replace the drier. If you find a flattened or kinked hose: replace the hose. If the compressor pistons have worn out: replace the compressor. If there is a shortage of refrigerant: add refrigerant. If there is a leaking compressor head gasket: replace the head gasket.Nov 11, 2022 · Low suction pressure and high head pressure is a condition where there is a decreased refrigerant pressure in the AC system and at the same time a high output pressure in a compressor. This condition is mainly caused by a defective or malfunctioning TXV valve. An expansion valve is a device that regulates the flow of the liquid refrigerant into ... In this guide we are going to explain everything you need to know about symptoms of bad TXV and how to properly diagnose it. The symptoms of a bad TXV include high superheat, low superheat, high subcooling, low suction pressure and low head pressure. However you might need to take additional diagnostics steps to rule out other …Aug 1, 2013 · The high head leads to poor heat rejection and the higher pressures can force more of the available refrigerant into the evaporator and show up as normal or high suction pressure with normal or low superheat. Also make sure the outdoor fan motor is running in the proper direction. Reply. How to Check Subcooling. Attach the thermometer to the liquid line. This time, near the condenser. Then take the head pressure in Psi and convert it to the temperature on the pressure/temperature chart. Assuming you are dealing with a R22 system, let’s say the head pressure is 260Psi. This will convert to 120F.Low suction pressure causes. low suction pressure is developed in the refrigeration system. Some of the most probable causes are as below, The coil is covered with dust or frost. Restriction in the refrigerant line. Filters and strainers are dirty. Faulty fan motor. Low room temperature. Faulty compressor.Mar 24, 2023 · Low suction pressure and low head pressure can cause decreased cooling capacity, reduced energy efficiency, and increased wear and tear on the compressor. TXV failure can also be caused by a rub out on the bulb tube and an external equalizer without a core depressor installed on a port that has a Schrader core in place. Jack Ma's Ant Group and Alibaba have come under increasing regulatory pressure from Chinese authorities in recent months. Jump to Alibaba jumped as much as 5% on Tuesday after CNBC...First, we must be aware that a restriction exists in the first place. In the case of the most common liquid line restrictions on HVAC equipment (with no receiver), we will see low suction pressure, high superheat, and normal to high subcooling. (Note: high head pressure isn't typically an indicator of a restriction!) In those cases, we know ...Read also: R410a Pressure Chart High and Low Side. psi: Pound per square inch, unit of pressure. FAQ What is the normal suction pressure on a 404a walk in the freezer? The normal suction pressure on a 404 a walk in freezer is around 10-20 psig (10 is ideal) on the suction side if working properly. And the high side is about 180 or so.Watch on. Compression ratio is the ratio of head pressure to suction pressure in an HVAC/R unit. Generally, compression ratios approach 2.5:1 on high-efficiency, 16+ SEER A/C systems. The highest compression ratio in A/C compressors is typically 11:1. Refrigeration compression ratios tend to be quite a bit higher (up to 26:1).410a low suction pressure. I injected super seal in a 410a system that had a tiny leak that I could not find. 2 years later I come across the problem of low suction pressure normal head pressure. Replaced txv and had same problem. Replaced compressor and had the same problem. Could the super seal be clogging the txv or evaporator or condenser ...R22 changes from a liquid to a gas in the evaporator coils of the air handler. Normal temperatures: With compressor running and as reference, on a 90 degree F. day: - Goodman runs 45degrees F on low pressure side and 115degrees F on high pressure side. - 2 ton York runs 40degrees F on low pressure side and 110degrees F on high …What should my normal operating pressures on 410a systems be? R410a suction pressure may be around 120psi, and R410a head pressure may be anywhere from 225psi to 350psi. Many conditions could apply here, there’s absolutely ‘no’ set point pressure for 410a, r22, or anything else. Educate yourself on whats going on in the heat transfer process.They seem low, check pressure at the compressor, unless there's a long distance between the evap and the cond unit it should get you close enough. your pressures are low, 200-225/55-60 would be closer 90* SCT would be 200psig and 25* SST would be 60ish ... with 175 head 50 box temp i would expect suction to be low 30s to 20s. ice …The pressure for an ordinarily operating R134a is between 22 and 57 pounds per square inch (PSI). Remember, there are two sides to the chart; we have the low and the high. Therefore in a normal R134a, the low-pressure side is 90 degrees or less, and the PSI should be close to 30.Oct 7, 2023 · Pressure gauges provide readings of the condensing and suction pressures, allowing technicians to monitor and adjust the head pressure as needed. B. Measuring Head Pressure in Refrigeration Systems To measure head pressure in refrigeration systems, technicians connect pressure gauges to the service ports on the high and low sides of the system. I have a suction pressure of 70, converted temp of 41, suction line temp of 51, head pressure of 250, converted temp of 117, head line temp of 96. Air entering condenser is 82 and exit is 100. Air entering evaporator is 76 and exiting is 52.If this is so always evaporating above zero, 4 or 5 deg celcius, R407c will have a low pressure (suction ) of about 50 psi. and a high pressure ( discharge ) of about 280 psi, which is about 55 deg celcius, cooling cycle. Standing pressure ( system not running ) will depend on surrounding temperature of outdoor unit.1 Answer. Hi, High head and a low suction pressure can indicate a couple of different things. One, condenser coil very dirty and needs to be washed very well. This will bring your head pressure down but let it run back up to normal engine temperatures. If the head is ok after you clean it, and suction is even lower, you may still be low on charge.Gonzo, if your evap was dirty you would have a low suction and low superheat. Not dirty evap let that go. High suction low head, with 100 lb suc and 100 degree ambient your head should be quite a bit higher. Really need the amp draw of comp and rated RLA but appears to be a compressor issue. pressure is the pressure required to boil a liquid at a given temperature. Soda water is a good example of a high vapor pressure liquid. Even at room temperature the carbon dioxide entrained in the soda is released. In a closed container, the soda is pressurized, keeping the vapor entrained. Vapor Pressure 0 5 10 15 20 25 40 60 80 100 120 140 ... One of the leading causes of low suction pressure is refrigerant leakage. When refrigerant leaks occur, the system's refrigerant charge decreases, resulting in reduced pressure levels. Leaks can occur at various points, including connections, joints, valves, or even within the coils themselves. 2. Dirty Evaporator or Condenser Coils.Pressure gauges provide readings of the condensing and suction pressures, allowing technicians to monitor and adjust the head pressure as needed. B. Measuring Head Pressure in Refrigeration Systems To measure head pressure in refrigeration systems, technicians connect pressure gauges to the service ports on the high and low …180 suction line pressure 320 discharge 10 degree temp split. No temp difference across the filter drier. I cleaned coils and checked airflow just to eliminate the variables. I recovered the refrigerant, changed the filter drier, charged about 2lbs before starting the compressor and the low side shot right up to 170. System holds about 8 lbs total. The normal operating pressures for R404A in a walk-in cooler typically range between 55-70 psi on the low side and 210-250 psi on the high side. However, these pressures can vary based on the specific application and ambient conditions. Typically, for a properly charged R-410A system, the low-side (suction) pressure may range from 120 to 150 psi, and the high-side (discharge) pressure may range from 300 to 450 psi, depending on factors such as temperature and load. ... Normal operating temperatures for R-410A systems typically range between 35 to 60 degrees …Low condensing (head) pressure; Low condenser split; Normal to a bit high condenser subcooling; and/or; May be a local cool spot or frost after the restriction. ... The compression ratio will be high from the low suction pressure causing low volumetric efficiencies. The compressor will simply not be pumping much refrigerant, and all components ...If the system suction pressure on a fixed metering device type unit is too high; the potential causes are; C. Flooded Evaporator Coil, High Evaporator Head Load, Dirty Condenser Coils, Compressor Valve Failures. TXV system problems can exhibit the five following symptoms: a. Normal suction pressure & superheat, with low or high …Apr 22, 2024 · If the suction pressure is 45 psi, (which converts to 22 ° F) and the suction temp is 32 ° F, the system still has 10 ° F of superheat. The fact that these readings are normal indicates the low suction pressure is not caused by low refrigerant, but insufficient heat getting to the evaporator. CAUSE #2: Defective, plugged, or undersized ... Came across another Rheem recently with a high head pressure in heat mode. Its a RPPL. Head pressure slowly climbs to above 600, suction pressure is normal not low at all. Airflow inside is okay... static pressure is .7inWc. Coils are clean. In cooling mode the charge looks damn near perfect... 11 degrees subcooling and 9-11 degrees superheat. Below we list a dozen causes of high head pressure in an air conditioner or heat pump compressor motor. Of these, debris clogging or malfunctioning TXVs seem to be the most common problems. Air contamination in the refrigerant system. Air flow blocked across the condensing coil. Low condenser airflow will show up as high head pressure, normal ... pressure is the pressure required to boil a liquid at a given temperature. Soda water is a good example of a high vapor pressure liquid. Even at room temperature the carbon dioxide entrained in the soda is released. In a closed container, the soda is pressurized, keeping the vapor entrained. Vapor Pressure 0 5 10 15 20 25 40 60 80 100 120 140 ... im in the field 3 years now and this is the first time ive come across this. residential split system 1.5 tons and i had a good suction pressure but my head …R448a PT chart is quite useful in HVAC. It tells you what is the pressure of R488a liquid and vapor refrigerant from -49°F to 150°F.Inversely, you can also tell the temperature of R488a refrigerant if you know the pressures (from 0.7 psig to 462.8 psig).Further on, you will find an online R448a pressure temperature chart as well as a printable R448a PT … pressure is the pressure required to boil a liquid at a given temperature. Soda water is a good example of a high vapor pressure liquid. Even at room temperature the carbon dioxide entrained in the soda is released. In a closed container, the soda is pressurized, keeping the vapor entrained. Vapor Pressure 0 5 10 15 20 25 40 60 80 100 120 140 ... We will first examine the low-pressure side of the system, otherwise known as the vapor or suction line. During air conditioning mode, the pressure on the vapor line of an R-410A system will be somewhere between 102 to 145 PSIG. If the system had R-22, the vapor pressure would be between 58 to 85 PSIG but these pressures will be dependent on ...Sep 26, 2022 · Low Load. While we often think of the combo of low suction, superheat, and head pressure as being caused by low airflow, it actually falls under a larger heading of low evaporator load. That simply means that the quantity of heat being picked up in the evaporator is lower than the refrigerant mass flow rate requires for the desired operation. a. Check the setting of high and low pressure cutout switches. b. Check oil level in the compressor, it should be at or above the centre of the sight glass. c. Open all shutoff valves in the system except bypass valves used elsewhere in the system. d. Valves in lines connecting suction gages should be closed. e.When it comes to upgrading your shower experience, one of the key factors to consider is water pressure. If you’re looking for a high-pressure shower, you might be torn between cho...If refrigerant is added under those conditions, when the problem is a restricted TXV, the head pressure may increase and the receiver may overfill, creating a potentially dangerous head pressure. In contrast, an overfed system exhibits: High suction pressure; Low superheat; Low-to-normal liquid pressure

Watch on. Compression ratio is the ratio of head pressure to suction pressure in an HVAC/R unit. Generally, compression ratios approach 2.5:1 on high-efficiency, 16+ SEER A/C systems. The highest compression ratio in A/C compressors is typically 11:1. Refrigeration compression ratios tend to be quite a bit higher (up to 26:1).. Mercedes jackson mobile al

low head pressure normal suction

Big fare sale to Europe has tickets to popular destinations such as Portugal available for more than 50% off normal prices. Right now is a great time to visit Europe. Flights to so...A typical R-22 system operating normally with a head pressure of 260 psig at a 120 degree condensing temperature and a low side pressure of 76 psig at a 45 degree evaporator saturation temperature will find the equivalent pressures in a R-410A system to be much higher. ... over the reciprocating compressor when comparing volumetric …How to Fix Low Suction Pressure Issues. If there is excessive moisture in system: replace the drier. If you find a flattened or kinked hose: replace the hose. If the compressor pistons have worn out: replace the compressor. If there is a shortage of refrigerant: add refrigerant. If there is a leaking compressor head gasket: replace the head gasket.We will first examine the low-pressure side of the system, otherwise known as the vapor or suction line. During air conditioning mode, the pressure on the vapor line of an R-410A system will be somewhere between 102 to 145 PSIG. If the system had R-22, the vapor pressure would be between 58 to 85 PSIG but these pressures will be dependent on ...There are three main reasons why a reciprocating compressor will simultaneously have a low head pressure and a high suction pressure. • Bad (leaky) compressor valves; • …The technician instantly notices the suction pressure is reading 50 psig (26°). For the outdoor temperature and humidity conditions that day, the normal suction pressure should be about 70 psig (41°). The head pressure also is low at 190 psig for the 90° day. The head pressure should be in the 255-265 psig range.normal suction low head pressure. im in the field 3 years now and this is the first time ive come across this. residential split system 1.5 tons and i had a good suction pressure but my head pressure was super low, only 150-160. the strange thing is operations seemed pretty normal. cold suction line, warm liquid line, condenser was putting out ...The most common causes of pressure in the head and face include allergies, ear infections, the common cold, muscle tension, sinusitis, stress and tension headaches. Increased intra...When it comes to upgrading your shower experience, one of the key factors to consider is water pressure. If you’re looking for a high-pressure shower, you might be torn between cho...Pressure gauges provide readings of the condensing and suction pressures, allowing technicians to monitor and adjust the head pressure as needed. B. Measuring Head Pressure in Refrigeration Systems To measure head pressure in refrigeration systems, technicians connect pressure gauges to the service ports on the high and low sides of the system.Posts. 4,910. Post Likes. Originally Posted by otto8. I am working with Larkin walk in freezer.. I just wanted to know what are normal pressures for freezers. Its 404 refrigerant. I have worked on true reach in freezers and I was told my low side should be at 13 psi and high side at 250.Jul 8, 2019 · High Suction Pressure R-410a. i went to check an 3.5 ton a/c brand is a ICP (international comfort products) Model WAPL424A1, not cooling my pressures were low side 185 to 190 and high side was around 350 on a 107F hot day. It has a piston as a metering device and compressor was running at 11.50 amps and RLA is 17.25 amps. .